An air compressor is a device that converts power (using an electric motor, diesel or gasoline engine, etc.) into potential energy stored in pressurized air. By one of several methods, an air compressor forces more and more air into a storage tank, increasing the pressure. When tank pressure reaches its engineered upper limit, the air compressor shuts off. The compressed air, then, is held in the tank until called into use.The energy contained in the compressed air can be used for a variety of applications, utilizing the kinetic energy of the air as it is released and the tank depressurizes. When tank pressure reaches its lower limit, the air compressor turns on again and re-pressurizes the tank. An air compressor must be differentiated from a pump because it works for any gas/air, while pumps work on a liquid.

SCY Portable Diesel Screw Air Compressors(Low, Medium Pressure Series)

SCY Portable Driven Screw Air Compressors(Low,Medium Pressure Series) for Sale in Yugong
SCY Portable Driven Screw Air Compressors(Low,Medium Pressure Series)

SCY Portable Driven Screw Air Compressors(Low,Medium Pressure Series) for Sale in Yugong
SCY Portable Driven Screw Air Compressors(Low,Medium Pressure Series) for Sale

Model Nominal Pressure(Mpa) F.A.D(Free Air Delivery(m³/min) Oil Content(ppm) Diesel Power(HP) Weight (kg) Unit Dimensions(mm)
40SCY 0.6 4.2 ≤6 37(50) 860 2400×1330×1480
58SCY-8 two wheels 0.8 7 ≤6 58(80) 1550 3140×1740×1900
110SVY-8 four wheels 0.8 12 ≤6 110(150) 2180 3120×1630×2290
110SCY-10 two wheels 1.0 12 ≤6 110(150) 2130 2890×2020×2270
110SCY-10 four wheels 1.0 12 ≤6 110(150) 2180 3120×1630×2290
110SCY-14.5 two wheels 1.45 10 ≤6 110(150) 2130 2890×2020×2270
110SCY-14.5 four wheels 1.45 10 ≤6 110(150) 2180 3120×1630×2290
138SCY-14.5 two wheels 1.45 13 ≤6 140(180) 2384 3350×2060×2350
139SCY-13 four wheels 1.3 15 ≤6 140(180) 2580 3650×1700×2040
141SCY-13 four wheels 1.3 15.5 ≤6 140(180) 2510 3650×1700×2040
180SCY-8 four wheels 0.8 20 ≤6 179(240) 3428 3720×1970×2250

Product Features:

  1. High quality diesel engine package.
  2. Full automatic control and protection system.
  3. No leaky capacity control.
  4. Luxury luminous micro-computer dashboard.
  5. All-weather high-altitude models (specially produced 5500m altitude unique organic type).
  6. Equipped with advanced filters with safety filter.
  7. The overall upgrade of power, more energy-saving and environmentally friendly.

Request A Quote

 

SCY Portable Diesel Driven Screw Air Compressors(High Pressure Series)

SCY Portable Driven Screw Air Compressors(High Pressure Series) for Sale in Yugong
SCY Portable Driven Screw Air Compressors(High Pressure Series)
Model Nominal Pressure(Mpa) F.A.D(Free Air Delivery(m³/min) Oil Content(ppm) Diesel Power(HP)  Diesel Power(HP)  Weight (kg) Unit Dimensions(mm)
168SCY-17 four wheels 1.7 16 ≤6 162(220) 2550 3620×1950×2200
177SCY-17 four wheels 1.7 16 ≤6 177(240) 3760 3720×1970×2250
181SCY-17 two wheels 1.8 17 ≤6 181(260) 3650 3600×1870×2660
186SCY-18 four wheels 1.8 18 ≤6 191(260) 3760 3600×1870×2660
198SCY-18 four wheels 1.8 18 ≤6 191(260) 3900 3720×1970×2550
250SCY-18 four wheels 1.8 23 ≤6 295(400) 4800 3810×2000×2900
228SCY-21 2.1(Two Stage Compression) 20 ≤6 221(300) 4060 3600×1870×2550
300SCY-24 2.4(Two Stage Compression) 30 ≤6 309(420) 4910 4150×1950×2900

Request A Quote

 

Diesel Stationary Screw Air Compressor Special for Deep Well Drilling

Diesel Stationary Screw Air Compressor Special for Deep Well Drilling for Sale
Diesel Stationary Screw Air Compressor Special for Deep Well Drilling

 

Model Nominal Pressure(Mpa) F.A.D(Free Air Delivery(m³/min) Oil Content(ppm) Diesel Power(HP) Weight (kg) Unit Dimensions(mm)
S55 1.7 17 ≤6 191(260) 3420 3720×1970×2550
S70D 2.1(Two Stage Compression) 20 ≤6 221(300) 3720 3380×1870×2170
S95D 2.3(Two Stage Compression) 27 ≤6 295(400) 4270 3660×2000×2500
S100D 2.4(Two Stage Compression) 29.5 ≤6 309(420) 4430 3700×1950×2280
S105D 2.5(Two Stage Compression) 30 ≤6 368(500) 4980 3850×1950×2380
S120D 2.5(Two Stage Compression) 35 ≤6 375(510) 5300 3850×2010×2150

Request A Quote

ZDY Electric Screw Air Compressors(Low,Medium,High Pressure Series)

Product Features:

  1. Heavy duty SKF bearings, advanced single stage, or dual stage made for ZEGA oil injected air end.
  2. Energy saving full series, class 2 energy efficiency, extra large air displacement, more cost saving.
  3. Computerized automatic control and protection system.
  4. Error free capacity control, unique ZEGA only electrical system with twice the operation range.
  5. High quality heavy duty filtration system with safety filters.
ZDY Electric Screw Air Compressors(Low,Medium,High Pressure Series) for Sale
ZDY Electric Screw Air Compressors(Low,Medium,High Pressure Series)
Model Nominal Pressure(Mpa) F.A.D(Free Air Delivery(m³/min) Oil Content(ppm) Motor Power(KW) Weight (kg) Unit Dimensions(mm)
ZDY13.6-8 0.8 13.6 ≤5 75 1956  

2280×1656×1970

ZDY12-10 1.0 12 ≤5 75 1832 2880×1656×1970
ZDY12-13 1.3 12 ≤5 90 2273 2280×1656×1970
ZDY16-13  

1.3

16 ≤5 132 3175 3340×1640×2270
ZDY21-13  

1.3

21 ≤5 185 3395 3340×1640×2270

Request A Quote

 

SCF Stationary Screw Air Compressors

Product Features:

  1. High efficiency, more energy saving especially for long term applications(nation agency certified report).
  2. Patented technology of industrial styling and product design. Compact size, optimized layout for easy maintenance and operation with application of engineering principals.
  3. World class oil-injected and positive displacement air ends, global best molded line design for high efficiency with low noise, low fuel cost and low maintenance cost.
  4. PLC programmable automatic protection system.
  5. Reliable VFD optional (Variable Frequency Drive).
  6. 132SCF-8, equipped with hidden lifting bracket, extreme convenient for lifting the unit.
  7. New 2-stage compression, superior in energy saving.
SCF Stationary Screw Air Compressors for Sale
SCF Stationary Screw Air Compressors
Model Nominal Pressure(Mpa) F.A.D(Free Air Delivery(m³/min) Outlet Temperature(℃ Oil Content(ppm) Motor Power(KW) Weight (kg) Unit Dimensions(mm) Drive Mode)
7.5SCF-8 0.8 1.12 ≤Environment+8 ≤3 7.5(10) 240 950×580×900 Belt
11SCF-8 0.8 1.6 ≤Environment+8 ≤3 11(15) 330 1100×700×982 Belt
15SCF-8 0.8 2.3 ≤Environment+8 ≤3 15(20) 380 1100×700×982 Belt
18.5SCF-8 0.8 3.2 ≤Environment+8 ≤3 18.5(25) 480 1300×800×1000 Belt
22SCF-8 0.8 3.6 ≤Environment+8 ≤3 22(30) 510 1450×890×1000 Direct Acting
30SCF-8 0.8 5.07 ≤Environment+8 ≤3 30(40) 700 1480×900×1180 Belt
37SCF-8 0.8 6.5 ≤Environment+8 ≤3 37(50) 730  

1580×980×1180

Direct Acting
45SCF-8 0.8 8.0 ≤Environment+8 ≤3 45(60)  705 1560×1000×1480 Direct Acting
55SCF-8 0.8 10 ≤Environment+8 ≤3 55(75) 960 1750×1100×1350 Direct Acting
75SCF-8 0.8 13.6 ≤Environment+8 ≤3 75(100) 1360 2160×1200×1453 Direct Acting
90SCF-8 0.8 16.5 ≤Environment+8 ≤3 90(120) 1480 2160×1200×1453 Direct Acting
110SCF-8 0.8 20 ≤Environment+8 ≤3 110(150) 2400 2400×1400×1705 Direct Acting
132SCF-8 0.8 24 ≤Environment+8 ≤3 132(180) 2500 2400×1400×1705 Direct Acting
160SCF-8 0.8 29 ≤Environment+8 ≤3 160(220) 2900 2645×1550×1770 Direct Acting
185SCF-8(380V) 0.8 33 ≤Environment+8 ≤3 185(250) 3080 2645×1550×1770 Direct Acting
250SCF-8(380V) 0.8 43 ≤Environment+8 ≤3 250(330) 5000 3520×1883×1990 Direct Acting
250SCF-8(10KV) 0.8 43 ≤Environment+8 ≤3 250(330) 5700 3520×1883×1990 Direct Acting
90SCFT( Two Stage Compression) 0.8 20 ≤3 90(120) 2160 2680×1459×1880 Direct Acting
110SCFT(Two Stage Compression) 0.8 24 ≤3 110(150) 3000 2880×1570×1880 Direct Acting

Request A Quote

Electric Motor Driven Portable (Open Frame) Screw Air Compressors

Product Features:

  1. Special design for narrow space applications such as tunnels and subways.
  2. Easy assembly and disassembly for easy transportation.
  3. Air cooling or water cooling systems to choose for different environment.
  4. Super strong protection of power pack for the worst air environment.
  5. Automatic operation and protection system.
  6. Super large power capacity for longer life.
Electric Motor Driven Portable(Open Frame) Screw Air Compressors for Sale
Electric Motor Driven Portable(Open Frame) Screw Air Compressors
SKY Model Nominal Pressure (Mpa) F.A.D(m³/min) Noise Outlet Temperature(℃) Oil Content(ppm) Motor Power(HP) Weight(kg) Unit Dimensission) Drive Mode
22SKY-6 0.6 4.6 70 ≤Environment+8 ≤3 22(30) 550 1900×920×1160 Belt
30SKY-8 0.8 5.0 70 ≤Environment+8 ≤3 30(40) 550 1900×920×1160 Belt
30SKY-8 0.8 5.0 70 ≤Environment+8 ≤3 30(40) 550 1900×920×1160 Direct Acting
45SKY-7 0.7 7.0 75 ≤Environment+8 ≤3 45(60) 850 1900×920×1250 Belt

Request A Quote

How to Improve the Air Compressor Exhaust Volume?

  1. Clean cylinders and other parts as necessary.
  2. Correctly choose the size of the clearance volume.
  3. Adopt advanced cooling system.
  4. Maintain the tightness of the piston ring.
  5. Reduce the resistance when the gas is inhaled.
  6. Maintain the tightness of the valve and exhaust valves.
  7. Maintain the sensitivity of the suction and exhaust valves.
  8. Inhalation of drier and cooler gases.
  9. Appropriately increase the speed of the air compressor.
  10. Maintain the tightness of the output lines, valves, air tanks and coolers.

Check the Air Compressor Before Starting:

  1. Confirm that the air compressor system maintenance work has been completed, the work ticket is recovered, and the measures have been resumed.
  2. Check the air compressor control panel emergency stop button in the reset state.
  3. Check that the oil level in the air separator of the air compressor is normal and the oil quality is qualified.
  4. Check that all parts of the air compressor are normal.
  5. Check that the air compressor power source, control power has been sent, and the control panel is displayed correctly.
  6. Check that the air compressor system is drained.
  7. Check that the air compressor outlet manual valve and the dryer outlet valve are closed ( the standby state should be in the open position).
  8. Check that the transmitters of the air compressor are in normal use.
  9. Turn on the air supply cooling water supply and return valve of the air compressor, check that the cooling water enters the water normally, and the system has no leakage.

Air Compressor System Operation Precautions:

  1. The door and panel must be closed when the air compressor is running.
  2. After the air compressor is inspected, the motor should be tested and the belt pulley should be connected after confirming that the direction of rotation is correct.
  3. Check the oil level of the oil and gas separator after each stop, the oil level should be above the minimum mark, otherwise contact the oil in time.
  4. When there is freezing or the air compressor has a long downtime, the cooling water must be drained and the water drained.
  5. The air compressor system and each compressed air line are drained twice per shift.
  6. The minimum and maximum temperatures of the air compressor room are controlled at 1℃and 40℃, respectively.
  7. Winter operation should be put into the gas storage tank hydrophobic electric heating device to prevent the freezing of the hydrophobic pipe and effect the normal hydrophobicity.
  8. After the air compressor is started or interlocked in the DCS, it must be sent to the site for a comprehensive inspection.
  9. Before the drying device is put into operation, confirm that the gas valve on the heater is turned on to prevent the heater from burning without compressed air.